Haiwu CFD
CFD air-wall type water-refrigerant double-coil air conditioner
Distributed architecture with reliable cooling system, supporting modular construction; No chiller and chilled pump, resulting in few fault points; Simplified piping design enables shorter construction cycles; Fewer intermediate heat exchanges result in a low CLF of the system; 100% utilization of natural cooling; The inverter compressor provides supplemental cooling on demand, improving rated COP
Supplied to order — the manager will confirm the lead time
The price depends on volume and configuration — we send a quote within one working day.
Specifications
Capacity and efficiency
- Использование естественного холода
- 100 %
- Рост COP
- 20 %
- Снижение заправки хладагента
- 76 %
Haiwu CFD
Distributed architecture with reliable cooling system, supporting modular construction; No chiller and chilled pump, resulting in few fault points; Simplified piping design enables shorter construction cycles; Fewer intermediate heat exchanges result in a low CLF of the system; 100% utilization of natural cooling; The inverter compressor provides supplemental cooling on demand, improving rated COP
Надёжность
Нет чиллера и насосов — мало точек отказа. Встроенный фреоновый контур без риска возврата масла, подходит для длинных трасс и больших перепадов высот.
Энергоэффективность
Без фальшпола сопротивление воздуха ниже на 26 %, потребление вентиляторов — на 45 %. Среднегодовой CLF не выше 0,077.
Управление и мониторинг
ПЛК-управление: отображение режимов, самодиагностика, мониторинг и самооптимизация энергоэффективности.
Distributed architecture with reliable cooling system, supporting modular construction; No chiller and chilled pump, resulting in few fault points; Simplified piping design enables shorter construction cycles; Fewer intermediate heat exchanges result in a low CLF of the system; 100% utilization of natural cooling; The inverter compressor provides supplemental cooling on demand, improving rated COP by 20%; Built-in refrigerant system suitable for compact rooftop installations; refrigerant charge reduced by 76%, eliminating oil return risks and supporting long piping with large height differences.
Where it is used
- Data centre